Water Resistant Insulin Pump Case by AquaPac (158)

Water Resistant Insulin Pump Case by AquaPac (158)
Click To Enlarge
  • Item #: AQUA-158
  • Manufacturer: AquaPac

This water resistant insulin pump is designed by AquaPac. We all know that delicate Insulin Pumps and water don't often mix well, so this waterproof case allows the user to bath, swim or paddle with peace of mind. Think of the freedom this simple case will provide as now your device is protected by one of the best waterproof case manufactures and one of the strongest warranties on the market. This case protects the pump from dust, dirt, and sand while giving the wearer full access to the device.

Supplied with a belt, or feed your own belt through the case Like most of Aquapac's cases it'll float if you drop it in the water. The seams are high-frequency welded to form a super-strong bond. The Aquaclip® (a patented, ultra-secure, rustproof, injection-molded plastic seal) opens and closes with a simple twist of two levers, and everything stays in one piece even when open. Comes supplied with: Adjustable belt

Specifications:
  • Color: Cool Grey
  • Materials: TPU
  • Full 5-Year Warranty: All Aquapacs come with a 'Full 5-Year Warranty
  • Water resistant design
  • Full access to the device
' What does 'Temporary Immersion' Mean? The Wire-Thru Aquaclip® sealing system used on this Aquapac has been tested to the waterproofing level IPX7. This means that it is OK for rain, showering and sea-spray, as well as quick submersion in water. It is not depth rated, so not for diving or snorkeling. Some customers have been happily surface swimming with this case for years, but make absolutely sure that the seal is clean, undamaged and properly closed. And avoid tugging on the tube or wire. Important Note regarding Insulin Pumps and Aquapac's case Aquapac have commissioned research by Imperial College London into the use of the 158 (Insulin Pump case) and 558 (Connected Electronics case) after receiving a large number of customer inquiries regarding their suitability for use with insulin pumps. Results show that, in some circumstances, insulin flow rate can be reduced by the case. In particular, low flow rates are impeded, and as such Aquapac can make no claim regarding the suitability of these cases with insulin pumps. Use of these cases with insulin pumps is entirely at the discretion of the user. Aquapac has been advised to recommend that users of Aquapac cases with insulin pumps regularly check their blood sugar levels. The tests were conducted by Imperial College of Science, Technology and Medicine using a Roche Accu-Check Spirit insulin pump at a temperature of 20C at flow rates of 2U/hr and 10U/hr. The amounts of insulin delivered over 60 minutes observed were as follows:
  • 2U/hr not in a case - 0.0131g (flow rate of 100%)
  • 2U/hr in Aquapac 150 - 0.0106g (flow rate of 81%)
  • 2U/hr in Aquapac 150 - 0.0056g (2nd test model) (flow rate of 42%)
  • 2U/hr in Aquapac 550 - 0.0121g (flow rate 92%)
  • 10U/hr not in case - 0.0864g (flow rate of 100%)
  • 10U/hr in Aquapac 150 - 0.0878g (flow rate of 100%)
  • 10U/hr in Aquapac 550 - 0.0903g (flow rate of 100%)
Full 5-Year Warranty on all Aquapacs come with a 'Full 5-Year Warranty'. Click here to find out more including returns, repairs and warranty service.
  * Marked fields are required.
Qty*
MSRP $65.00